Industrial Power Distribution Systems: Design, Protection and Fault Analysis – Paris, 30 Aug – 3 Sep 2027
DestinationParis
Dates30 August – 3 September 2027
Reference169_10418
This session
30 Aug – 3 Sep 2027
This Industrial Power Distribution Systems: Design, Protection and Fault Analysis session in Paris runs from Monday 30 August to Friday 3 September 2027 (week 35, Q3 2027). It is the 2nd of 2 dates in Paris in 2027, at a fee of 23,500 SAR, the same for each of them. Registration is open for this date. It is held in person at Right Bank business hotel.
DatesMonday 30 Aug – Friday 3 Sep 2027
Week35 of 2027
Duration5 days
Fee23,500 SAR
StatusOpen for registration
FormatIn person
VenueRight Bank business hotel
Programme overview
Introduction:
Industrial power distribution networks grow by piecemeal additions, and many plants run with unverified cable ratings, outdated fault levels and relay settings that no longer discriminate, so a single fault can trip a whole process unit. This Core Concept course equips plant electrical engineers to choose network configurations, estimate demand, size cables for voltage drop and fault duty, calculate short-circuit currents with the IEC 60909-0 method, select earthing arrangements, grade protection and trace faults to root cause. Participants build a Plant Distribution Study Workbook for a network from their own site.
Course Objectives:
Compare radial, ring and secondary selective network configurations and select one that meets plant continuity and maintenance needs
Estimate maximum demand from connected load lists using demand and diversity factors and size feeders, busbars and cables for current rating and voltage drop
Calculate balanced and unbalanced short-circuit currents with the IEC 60909-0 method and check equipment withstand against the results
Select system earthing and neutral earthing arrangements for low and medium voltage networks and explain their effect on earth fault current
Set overcurrent and earth fault relays with IDMT curves and produce a time-current coordination study that keeps discrimination between upstream and downstream devices
Investigate electrical faults and outages with structured root-cause analysis and record corrective actions against the single-line diagram
Target Audience:
Plant electrical engineers who extend, modify and keep records of site distribution networks
Facility and utilities engineers responsible for supply continuity to process units, buildings and critical loads
Project electrical engineers who prepare load lists, cable schedules and single-line diagrams for new installations
Protection and power system study engineers who calculate fault levels and set relays for industrial networks
Electrical reliability engineers who investigate trips, outages and repeat faults on plant feeders
Course Outline:
Day 1: Plant Network Configurations and Single-Line Diagrams
Industrial Supply Intake Arrangements and Voltage Level Selection
Radial, Ring Main and Secondary Selective Network Configuration Trade-Offs
Single-Line Diagram Conventions, Device Numbers and Drawing Revision Control
Connected Load List Preparation with Demand and Diversity Factors
Current-State Network Survey Checklist for an Existing Plant
Day 2: Cable Sizing, Voltage Drop and Short-Circuit Calculation
Cable Current Rating with Installation Method, Grouping and Ambient Derating Factors
Voltage Drop Calculation for Feeders and Motor Starting Conditions
IEC 60909-0 Equivalent Voltage Source Method and Voltage Factor c
Initial Symmetrical, Peak and Breaking Short-Circuit Current Calculation Sheets
Cable and Busbar Thermal Withstand Check Against Fault Duration
Day 3: System Earthing and Protection Coordination Studies
IEC 60364 TN-S, TN-C-S, TT and IT Earthing Arrangements for Low Voltage Plant
Solid, Resistance and Reactance Neutral Earthing and Zigzag Earthing Transformers
IDMT Relay Curves to IEC 60255-151 and IEEE C37.112 Characteristics
Pickup, Time Multiplier and Grading Margin Selection for Feeder Relays
Time-Current Coordination Plot Construction Across Fuses, Breakers and Relays
Day 4: Power Quality, Emergency Power and Fault Analysis
Power Factor Correction Capacitor Bank Sizing and Detuning Overview
Harmonic Sources, Distortion Indicators and Mitigation Options Overview
Standby Generator Sizing, Automatic Transfer Schemes and UPS Topologies
Electrical Fault Types: Symmetrical, Line-to-Earth, Line-to-Line and Double Line-to-Earth
Root-Cause Analysis of Plant Trips Using Event Records and Fault Trees
Day 5: Plant Distribution Study Workbook Build
Case Network Data Collection and Impedance Model Assembly
Load Flow and Voltage Profile Check for Normal and Contingency Cases
Fault Level Table and Equipment Duty Comparison for the Case Network
Relay Setting Schedule and Discrimination Review for the Case Network
Plant Distribution Study Workbook Peer Review and Improvement Actions
Skills You Will Gain:
Network Configuration Selection
Maximum Demand Estimation
Cable Sizing Calculation
Short-Circuit Current Calculation
Earthing Arrangement Selection
Relay Grading and Coordination
Standby Power Planning
Electrical Fault Root-Cause Analysis
Why Attend This Course:
Return with a Plant Distribution Study Workbook holding the load list, cable checks, fault levels and relay settings for a network from your own site
Spot undersized cables, overdutied equipment and non-discriminating relays before a fault exposes them
Explain network changes to project teams and management with calculations they can review and reuse
Compare distribution design practice with engineers from oil and gas, petrochemicals, manufacturing, water, mining and large facilities
Conclusion:
A plant distribution network stays dependable when its configuration, cables, fault levels, earthing and protection settings are checked as one system. The course moves from network configurations, single-line diagrams and load estimation, through cable sizing, voltage drop and IEC 60909-0 short-circuit calculation, to earthing arrangements and relay coordination, then to power quality, emergency power and fault root-cause analysis. The final day brings these together in a Plant Distribution Study Workbook ready for the next network modification or outage review.
Industrial Power Distribution Systems: Design, Protection and Fault Analysis runs in Paris over 5 days, with 2 upcoming dates in Paris. The course fee is 23,500 SAR.
Looking for training courses in Paris? CoreConsept Training Center delivers professional training in Paris across European regulatory frameworks, leadership, ESG, governance and project management — open enrolment programmes in central Paris.