Alarm Management for Process Control Systems: Philosophy, Rationalisation and Performance – Dubai, 8–12 Mar 2027
DestinationDubai
Dates8 – 12 March 2027
Reference187_10662
This session
8–12 Mar 2027
This Alarm Management for Process Control Systems: Philosophy, Rationalisation and Performance session in Dubai runs from Monday 8 March to Friday 12 March 2027 (week 10, Q1 2027). It is the 1st of 2 dates in Dubai in 2027, at a fee of 19,500 SAR, the same for each of them. Registration is open for this date. It is held in person at Five-star CBD venue.
DatesMonday 8 Mar – Friday 12 Mar 2027
Week10 of 2027
Duration5 days
Fee19,500 SAR
StatusOpen for registration
FormatIn person
VenueFive-star CBD venue
Programme overview
Introduction:
Alarm management fails quietly: control rooms accumulate standing alarms, chattering points and floods of low-value notifications until operators miss the one alarm that matters during an upset. This Core Concept course gives control, process and operations engineers a working method to run the alarm management life cycle, from writing an alarm philosophy through rationalising each alarm by consequence and operator response time to monitoring alarm rates and auditing the system. Participants build an Alarm Philosophy Extract, Rationalisation Record and Alarm Improvement Programme Plan from alarm data of their own plant.
Course Objectives:
Apply the alarm management life cycle described in ANSI/ISA-18.2-2016 and IEC 62682 to an existing control system
Draft an alarm philosophy document defining alarm criteria, priority matrix, class, HMI conventions and roles
Rationalise alarms by recording cause, consequence, corrective action, allowable operator response time and priority in a master alarm database
Specify suppression and design techniques such as deadband, on-delay, state-based alarming and shelving for nuisance and flood-prone alarms
Analyse alarm journal data for alarm rate, floods, chattering, standing alarms and top bad actors, and report performance against the philosophy targets
Plan management of change, periodic audit and an alarm improvement programme that keeps alarm performance from drifting back
Target Audience:
Control engineers who configure alarms in DCS, SCADA and PLC operator stations
Process engineers who define the consequence of deviations and the corrective actions operators must take
Operations engineers and control room shift leaders who respond to alarms and report nuisance alarms
Alarm coordinators who maintain the master alarm database and monthly alarm performance reports
Process safety and technical integrity engineers who review alarm changes under management of change
Course Outline:
Day 1: Alarm System Problems and the Alarm Management Life Cycle
Alarm, Event and Notification Definitions with Operator Action as the Alarm Test
Alarm Flood, Standing Alarm and Nuisance Alarm Failure Patterns in Past Incidents
Alarm Management Life Cycle Stages from ANSI/ISA-18.2-2016 and IEC 62682
EEMUA Publication 191, API 1167 and NAMUR NA 102 Guidance Compared
Alarm System Current-State Benchmark from a Sample Alarm Journal
Day 2: Alarm Philosophy Document and Master Alarm Database
Alarm Philosophy Contents Using ISA-TR18.2.1-2018 as the Structure
Priority Matrix from Consequence Severity and Allowable Operator Response Time
Alarm Classes, Highly Managed Alarms and Safety-Related Alarm Handling
Roles and Responsibilities: Alarm Owner, Alarm Coordinator and Operations Sign-Off
Master Alarm Database Field Structure and Configuration Export Reconciliation
Day 3: Alarm Identification and Rationalisation Workshop Method
Alarm Identification Sources: P&IDs, HAZOP Actions, LOPA Records and Operating Procedures
Rationalisation Meeting Method Following ISA-TR18.2.2-2016
Cause, Consequence, Corrective Action and Confirmation Record for Each Alarm
Alarm Setpoint Placement Against Process Dynamics and Response Time Margin
Duplicate, Redundant and Informational Alarm Removal Decision Criteria
Day 4: Alarm Design, Suppression, HMI and Performance Analysis
Deadband, On-Delay and Off-Delay Settings for Chattering Alarm Removal
State-Based Alarming, Logical Suppression and Flood Suppression Methods in ISA-TR18.2.4-2012
Shelving and Out-of-Service Controls with Time Limits and Authorisation
HMI Alarm Presentation: Alarm Summary, Colour Conventions and Audible Tones
Alarm Performance KPIs in ISA-TR18.2.5-2022: Alarm Rate per Operator, Floods, Chattering and Standing Alarms
Day 5: Alarm Data Case Study and Improvement Programme Build
Alarm Journal Case: Top Ten Bad Actor Analysis and Pareto of Alarm Load
Alarm Flood Case: Upset Sequence Reconstruction and Root Alarm Identification
Alarm Management of Change Checklist and Periodic Audit Protocol
Alarm Improvement Programme Roadmap with Milestones and Monthly KPI Report
Alarm Philosophy Extract, Rationalisation Record and Programme Plan Peer Review
Skills You Will Gain:
Alarm Philosophy Drafting
Alarm Rationalisation Facilitation
Priority Matrix Design
Master Alarm Database Management
Nuisance Alarm Diagnosis
Alarm Flood Analysis
Alarm Performance Reporting
Alarm Change Control
Why Attend This Course:
Return with an Alarm Philosophy Extract, Rationalisation Record and Alarm Improvement Programme Plan built from your own plant's alarm data
Reduce operator alarm load by removing chattering, duplicate and standing alarms with evidence from the alarm journal
Defend every alarm priority and setpoint change to operations and safety reviewers with a documented consequence and response time
Compare alarm practice with control room peers from oil and gas, petrochemicals, power, water and pharmaceutical plants
Conclusion:
An alarm system serves the operator only when every alarm needs a response, carries the right priority and arrives at a rate an operator can handle. The course moves from alarm failure patterns and the life cycle, through the alarm philosophy and master alarm database, to rationalisation, then to design and suppression techniques, HMI presentation and performance analysis. Participants leave with an Alarm Philosophy Extract, Rationalisation Record and Alarm Improvement Programme Plan ready for their next alarm review.
Alarm Management for Process Control Systems: Philosophy, Rationalisation and Performance runs in Dubai over 5 days, with 2 upcoming dates in Dubai. The course fee is 19,500 SAR.
Looking for training in Dubai? CoreConsept Training Center delivers professional courses in Dubai across leadership, governance, ESG, project management and digital transformation — open enrolment and in-house programmes for the Gulf region.