Electrical Equipment in Hazardous Areas: Ex Selection, Installation and Inspection – Dubai, 17–21 May 2027
DestinationDubai
Dates17 – 21 May 2027
Reference231_11295
This session
17–21 May 2027
This Electrical Equipment in Hazardous Areas: Ex Selection, Installation and Inspection session in Dubai runs from Monday 17 May to Friday 21 May 2027 (week 20, Q2 2027). It is the 2nd of 2 dates in Dubai in 2027, at a fee of 19,500 SAR, the same for each of them. Registration is open for this date. It is held in person at Five-star CBD venue.
DatesMonday 17 May – Friday 21 May 2027
Week20 of 2027
Duration5 days
Fee19,500 SAR
StatusOpen for registration
FormatIn person
VenueFive-star CBD venue
Programme overview
Introduction:
Electrical equipment in hazardous areas becomes an ignition source when a zone drawing is out of date, a motor carries the wrong temperature class, a flameproof joint is corroded or an intrinsically safe loop is extended without checking cable capacitance. This Core Concept course trains electrical and instrument staff to read area classification drawings, select Ex equipment from its marking, install cabling and glands correctly, and inspect and maintain protection concepts across their service life. Participants produce an Ex Equipment Register and Inspection Dossier for a plant area of their own.
Course Objectives:
Interpret hazardous area classification drawings for gas zones 0, 1 and 2 and dust zones 20, 21 and 22, including release sources and zone extents
Select Ex equipment by matching zone, gas group, temperature class and Equipment Protection Level to the marking on the nameplate and certificate
Verify an intrinsically safe loop by comparing barrier or isolator output values with field device input values and cable capacitance and inductance
Install Ex cabling, cable glands, stopping boxes and terminations so that the protection concept stays intact
Plan and record visual, close and detailed inspections and set inspection intervals from equipment condition and environment
Control repair, overhaul, modification and replacement of Ex equipment through an equipment register, certificates and change records
Target Audience:
Electrical technicians who install, terminate and maintain motors, lighting and junction boxes in classified areas
Instrument technicians who wire, loop check and maintain transmitters, analysers and intrinsically safe circuits
Electrical and instrument engineers who specify field equipment and review installation drawings for classified areas
Maintenance supervisors who plan Ex inspections, issue work to crews and sign off defect close-out
Commissioning and construction staff who hand over Ex installations to operations with complete records
Course Outline:
Day 1: Explosive Atmospheres and Hazardous Area Classification
Ignition Triangle, Flammable Limits, Flash Point and Autoignition Temperature of Gases and Vapours
Combustible Dust Clouds and Layers: Particle Size, Layer Ignition and Housekeeping
Gas Zone 0, 1 and 2 Definitions Using IEC 60079-10-1 Grade of Release and Ventilation
Dust Zone 20, 21 and 22 Definitions Using IEC 60079-10-2
Reading Area Classification Drawings, Zone Extents and Substance Data Schedules
Day 2: Protection Concepts, Gas Groups and Ex Marking
Gas Groups IIA, IIB and IIC and Temperature Classes T1 to T6
Flameproof Ex d Enclosures to IEC 60079-1: Flame Paths, Gaps and Bolting
Increased Safety Ex e to IEC 60079-7 and Pressurised Ex p to IEC 60079-2
Non-Sparking Ex n, Encapsulation Ex m, Oil Immersion Ex o and Powder Filling Ex q
Decoding Ex Marking, Equipment Protection Levels, ATEX Categories and IECEx Certificates
Day 3: Ex Equipment Selection, Intrinsic Safety and Installation Practice
Equipment Selection Matrix: Zone, Gas Group, Temperature Class and Ambient Range
Intrinsic Safety Levels ia, ib and ic to IEC 60079-11 with Zener Barriers and Galvanic Isolators
Grain or Powder Handling Walkthrough: Dust Layer, Enclosure Sealing and Surface Temperature
Detailed Inspection Checklist Completion and Defect Priority Ranking
Ex Equipment Register and Inspection Dossier Peer Review
Skills You Will Gain:
Area Classification Interpretation
Ex Marking Decoding
Protection Concept Recognition
Intrinsic Safety Loop Calculation
Cable Gland Installation
Ex Inspection Planning
Defect Grading
Ex Records Management
Why Attend This Course:
Return with an Ex Equipment Register and Inspection Dossier built for a plant area you work in
Tell at a glance whether a nameplate suits the zone, gas group and temperature class where the item is installed
Stop gland, flame path and loop extension errors before they reach an inspection finding or an ignition
Compare Ex practice with electrical and instrument staff from oil and gas, chemicals, pharmaceuticals, grain handling and utilities
Conclusion:
Equipment in explosive atmospheres stays safe only when classification, selection, installation and inspection agree with each other and with the records. The course moves from flammable and dust atmospheres and zone drawings, through gas groups, temperature classes, protection concepts and Ex marking, to equipment selection, intrinsic safety loop verification and cable gland practice, then to inspection grades, frequent defects, repair control and records. The final day applies the material in plant walkthroughs and produces an Ex Equipment Register and Inspection Dossier.
Electrical Equipment in Hazardous Areas: Ex Selection, Installation and Inspection runs in Dubai over 5 days, with 2 upcoming dates in Dubai. The course fee is 19,500 SAR.
Looking for training in Dubai? CoreConsept Training Center delivers professional courses in Dubai across leadership, governance, ESG, project management and digital transformation — open enrolment and in-house programmes for the Gulf region.