Power System Protection and Relaying: Schemes, Settings and Testing – Paris, 29 Mar – 2 Apr 2027
DestinationParis
Dates29 March – 2 April 2027
Reference247_11524
This session
29 Mar – 2 Apr 2027
This Power System Protection and Relaying: Schemes, Settings and Testing session in Paris runs from Monday 29 March to Friday 2 April 2027 (week 13, Q1 2027). It is the 1st of 2 dates in Paris in 2027, at a fee of 23,500 SAR, the same for each of them. Registration is open for this date. It is held in person at Right Bank business hotel.
DatesMonday 29 Mar – Friday 2 Apr 2027
Week13 of 2027
Duration5 days
Fee23,500 SAR
StatusOpen for registration
FormatIn person
VenueRight Bank business hotel
Programme overview
Introduction:
Power system protection and relaying decides whether a fault clears in milliseconds at one breaker or cascades into a wider blackout, yet many relay settings were calculated years ago, CT saturation was never checked and disturbance records sit unread. This Core Concept course equips protection engineers to design and verify relay schemes for lines, transformers, busbars and generators, calculate distance, differential and overcurrent settings, test numerical relays by secondary injection and read COMTRADE records after a trip. Participants build a Protection Setting Calculation and Relay Test Dossier for a scheme from their own network.
Course Objectives:
Calculate symmetrical-component fault currents and apparent impedances as seen by relays, and select CT and VT ratios, classes and knee-point voltages that stay out of saturation for through faults
Set phase and earth-fault overcurrent and directional elements (ANSI 50, 51, 67) and prove selectivity across zones of protection with local and remote backup
Define distance protection zones, reach and resistive coverage for overhead lines and cables, and choose a communication-aided scheme for the line
Configure biased differential protection (ANSI 87) for transformers, busbars and generators, including inrush and overexcitation restraint and stability checks
Specify generator protection functions such as loss of excitation, reverse power, negative sequence, stator earth fault and out-of-step, and justify each pickup and delay
Test numerical relays by secondary injection, verify IEC 61850 GOOSE trip paths at overview level and analyse COMTRADE disturbance records to confirm correct or incorrect operation
Target Audience:
Protection engineers who calculate, issue and revise relay setting files for transmission and distribution substations
Relay test and maintenance engineers who carry out secondary injection, scheme checks and periodic protection testing
Power plant electrical engineers responsible for generator, unit transformer and auxiliary protection
Substation engineers who review protection drawings, trip logic and interlocks for new bays and extensions
System operations and fault analysis engineers who investigate trips and maloperations from relay event and oscillography records
Course Outline:
Day 1: Protection Philosophy, Fault Quantities and Instrument Transformers
Zones of Protection, Overlap at Breakers and Primary Versus Backup Philosophy
Symmetrical Components and Sequence Networks for Relay Fault Studies
Apparent Impedance and Fault Current Phasors Seen From the Relay Location
Protection CT Accuracy Classes, Knee-Point Voltage and Saturation Checks
Protection VT Connections, Open-Delta Residual Voltage and Fuse Failure Supervision
Day 2: Overcurrent, Directional and Distance Schemes for Lines
ANSI 50, 51 and 67 Elements with IEC 60255-151 Inverse Characteristics
Directional Polarisation Methods and Sensitive Earth-Fault Detection
Mho and Quadrilateral Distance Characteristics and ANSI 21 Zone Reach Settings
Resistive Reach, Load Encroachment and Power Swing Blocking Logic
Permissive Underreach, Permissive Overreach and Blocking Teleprotection Schemes
Day 3: Unit Protection for Transformers, Busbars and Generators
Biased Percentage Differential Slope and Minimum Pickup Calculation
Transformer Differential Vector Group Compensation and Zero-Sequence Filtering
Second and Fifth Harmonic Restraint for Inrush and Overexcitation
High-Impedance and Low-Impedance Busbar Protection with Check Zone Logic
Restricted Earth Fault and Line Current Differential ANSI 87L Principles
Day 4: Generator Protection, Numerical Relays and Protection Communications
Stator Earth Fault Coverage Using Neutral Overvoltage and Third-Harmonic Schemes
Loss of Excitation ANSI 40, Reverse Power ANSI 32 and Negative Sequence ANSI 46 Settings
Out-of-Step ANSI 78, Volts per Hertz ANSI 24 and Frequency ANSI 81 Elements
Numerical Relay Architecture, Setting Groups and Programmable Trip Logic
Day 5: Setting Studies, Relay Testing and Disturbance Record Analysis
Setting Calculation Sheet Build for a Line, Transformer and Generator Bay
Secondary Injection Test Plan: Pickup, Timing, Distance Zone and Differential Slope Checks
End-to-End and Trip Circuit Tests with Lockout Relay ANSI 86 Verification
COMTRADE Record Analysis to IEEE C37.111 and IEC 60255-24 for a Maloperation Case
Protection Setting Calculation and Relay Test Dossier Peer Review
Skills You Will Gain:
Protection Fault Study
Instrument Transformer Dimensioning
Distance Zone Setting
Differential Scheme Configuration
Generator Protection Setting
Teleprotection Scheme Selection
Secondary Injection Testing
Disturbance Record Interpretation
Why Attend This Course:
Return with a Protection Setting Calculation and Relay Test Dossier for a line, transformer or generator bay from your own network
Find settings that overreach, underreach or lose stability on through faults before a real event exposes them
Explain a relay operation to operations and management with evidence taken from oscillography and event logs
Compare protection practice with engineers from utilities, power generation, oil and gas, petrochemicals and heavy industry
Conclusion:
Dependable protection comes from settings that are calculated, tested and checked against real disturbances. The course moves from zones of protection, sequence quantities and instrument transformers, through overcurrent, directional and distance schemes for lines, to unit protection of transformers, busbars and generators, then to generator functions, numerical relays and substation communications. The final day brings the work together in a Protection Setting Calculation and Relay Test Dossier that participants review with peers and apply to their next setting revision or trip investigation.
Power System Protection and Relaying: Schemes, Settings and Testing runs in Paris over 5 days, with 2 upcoming dates in Paris. The course fee is 23,500 SAR.
Looking for training courses in Paris? CoreConsept Training Center delivers professional training in Paris across European regulatory frameworks, leadership, ESG, governance and project management — open enrolment programmes in central Paris.