Generator Excitation Systems and AVR: Operation, Diagnostic Testing and Maintenance – Dubai, 30 Aug – 3 Sep 2027
DestinationDubai
Dates30 August – 3 September 2027
Reference253_11601
This session
30 Aug – 3 Sep 2027
This Generator Excitation Systems and AVR: Operation, Diagnostic Testing and Maintenance session in Dubai runs from Monday 30 August to Friday 3 September 2027 (week 35, Q3 2027). It is the 2nd of 2 dates in Dubai in 2027, at a fee of 19,500 SAR, the same for each of them. Registration is open for this date. It is held in person at Five-star CBD venue.
DatesMonday 30 Aug – Friday 3 Sep 2027
Week35 of 2027
Duration5 days
Fee19,500 SAR
StatusOpen for registration
FormatIn person
VenueFive-star CBD venue
Programme overview
Introduction:
Generator excitation systems decide whether a synchronous generator holds terminal voltage, shares reactive load and rides through grid disturbances, yet many plants run with AVR limiters never checked, brush gear worn and insulation tests trended by no one. This Core Concept course prepares plant electrical staff to operate, test and maintain static and brushless excitation, place the generator on its capability curve, synchronise units safely and read insulation, partial discharge and rotor test results. Participants build a Generator Condition Assessment and Overhaul Plan for a unit at their own site.
Course Objectives:
Interpret generator construction, nameplate ratings and the capability curve to keep a unit inside its stator, rotor and under-excitation limits
Explain and check static and brushless excitation hardware, AVR control loops and excitation limiters, and describe the power system stabiliser role at overview
Carry out synchronising and parallel operation, and share reactive power between units with droop or power factor control
Supervise generator cooling systems and recognise abnormal air, hydrogen and stator water conditions before they limit output
Perform and interpret insulation resistance, polarisation index, partial discharge and rotor winding tests and trend the results over time
Plan minor and major inspections, trace excitation and winding faults to root cause and compile a Generator Condition Assessment and Overhaul Plan
Target Audience:
Power plant electrical engineers responsible for generator and excitation system availability
Generator maintenance engineers and technicians who inspect, test and overhaul stators, rotors and exciters
Control room and unit operators who synchronise generators and control voltage and reactive power
Industrial and cogeneration plant engineers responsible for on-site generating units
Condition monitoring specialists who collect and trend insulation and partial discharge data
Course Outline:
Day 1: Synchronous Generator Construction, Ratings and Operating Limits
Cylindrical Rotor and Salient Pole Construction: Stator Core, Windings and Retaining Rings
Nameplate Ratings, Short-Circuit Ratio and Synchronous Reactance
Generator Capability Curve: Stator Heating, Rotor Heating and Under-Excitation Boundaries
Phasor Diagram Reading for Load Angle, Power Factor and Field Current
Unit Baseline Review Using Operating Logs and Previous Inspection Reports
Day 2: Excitation System Architecture and AVR Control Functions
Static Excitation: Thyristor Bridge, Excitation Transformer, Slip Rings and Field Flashing
Brushless Excitation: AC Exciter, Rotating Diode Rectifier and Permanent-Magnet Pilot Exciter
AVR Control Loop: Voltage Set Point, Error Signal, Gain and Response Tuning
Over-Excitation, Under-Excitation and Volts per Hertz Limiters in the AVR
Power System Stabiliser Purpose and Reactive Current Compensation at Overview
Day 3: Synchronising, Parallel Operation, Reactive Power and Cooling
Synchronising Checks: Voltage, Frequency and Phase Angle Matching with Synchroscope and Check Relay
Auto-Synchroniser Sequence and Consequences of Out-of-Phase Closure
Reactive Load Sharing Between Parallel Units Using Droop and Power Factor Control
Station Voltage and VAr Dispatch Instructions and Joint Reactive Control
Cooling Circuit Operation: Air, Hydrogen and Stator Water Systems with Seal Oil Monitoring
Day 4: Insulation Diagnostics, Condition Monitoring and Fault Cases
Insulation Resistance and Polarisation Index Testing of Stator and Rotor Windings
Off-Line Partial Discharge Measurement to IEC 60034-27 and IEC 60270
On-Line Partial Discharge Monitoring with HFCT Sensors and IEEE 1434 Trending
Rotor Winding Tests: Shorted Turn Detection, Recurrent Surge Oscillation and Pole Drop Test
Troubleshooting Field Failure, Diode Failure and Voltage Hunting with Protection Trip Records
Day 5: Major Inspection Case Work and Generator Condition Assessment Plan
Major Inspection Scope Case: Rotor Removal, Wedge Tightness and Stator Core Findings
Post-Overhaul Test Sequence Case: Open-Circuit Characteristic, AVR Step Response and Limiter Checks
Inspection Walkthrough Case: Stator End-Winding, Brush Gear and Cooler Condition
Generator Condition Assessment and Overhaul Plan Drafting
Overhaul Plan Peer Review and Outage Scope Challenge
Skills You Will Gain:
Capability Curve Interpretation
Excitation System Diagnostics
AVR Limiter Verification
Generator Synchronising Practice
Reactive Power Sharing
Winding Insulation Assessment
Partial Discharge Trending
Overhaul Scope Planning
Why Attend This Course:
Return with a Generator Condition Assessment and Overhaul Plan built from test data and inspection findings for a unit at your site
Recognise the early signs of diode, brush gear and insulation deterioration before they force an unplanned outage
Explain to operations why a unit must stay inside its capability limits and how excitation settings affect grid voltage
Compare generator operating and maintenance practice with engineers from utilities, oil and gas, petrochemicals and industrial cogeneration
Conclusion:
A generator stays available when its excitation is understood, its operating limits are respected and its insulation is tested and trended. The course moves from construction, ratings and the capability curve, through static and brushless excitation and AVR functions, to synchronising, reactive power control and cooling, and then to insulation, partial discharge and rotor diagnostics with fault cases. The final day applies this to inspection and overhaul cases and produces a Generator Condition Assessment and Overhaul Plan for the next outage.
Generator Excitation Systems and AVR: Operation, Diagnostic Testing and Maintenance runs in Dubai over 5 days, with 2 upcoming dates in Dubai. The course fee is 19,500 SAR.