Medical Device Risk Management and Quality Systems: ISO 14971 and ISO 13485 – London, 12–16 Jul 2027
DestinationLondon
Dates12 – 16 July 2027
Reference265_11774
This session
12–16 Jul 2027
This Medical Device Risk Management and Quality Systems: ISO 14971 and ISO 13485 session in London runs from Monday 12 July to Friday 16 July 2027 (week 28, Q3 2027). It is the 2nd of 2 dates in London in 2027, at a fee of 23,000 SAR, the same for each of them. Registration is open for this date. It is held in person at Central London four-star.
DatesMonday 12 Jul – Friday 16 Jul 2027
Week28 of 2027
Duration5 days
Fee23,000 SAR
StatusOpen for registration
FormatIn person
VenueCentral London four-star
Programme overview
Introduction:
Medical device risk management fails when hazards are listed once at design stage and never revisited, when quality records cannot show why a residual risk was accepted, and when complaints and field reports never reach the risk file. This Core Concept course takes manufacturers, distributors and hospital biomedical teams through device classification, an ISO 13485 quality management system and the ISO 14971 process: hazard identification, risk estimation and evaluation, risk controls, benefit-risk decisions and post-production information. Participants build a Device Risk Management File for a product from their own work.
Course Objectives:
Classify medical devices by intended purpose and risk class and set the quality and documentation effort each class demands
Apply ISO 13485 quality management system requirements to design controls, supplier control, traceability and process validation for devices
Conduct hazard identification, risk estimation and risk evaluation for a device against documented risk acceptability criteria
Select and verify risk control measures and justify residual risk through benefit-risk analysis as ISO 14971 describes it
Feed complaints, post-market surveillance data and vigilance reports back into the risk file and trigger field safety corrective actions or recalls
Compile a Device Risk Management File with the risk management plan, analysis records and risk management report
Target Audience:
Quality assurance staff responsible for device quality management system records, CAPA and supplier control
Regulatory affairs staff responsible for technical documentation and post-market reporting for device portfolios
Design and development engineers responsible for design inputs, verification and risk control implementation
Distribution and importer quality staff responsible for device storage, traceability, complaint handling and field actions
Hospital biomedical and clinical engineering staff responsible for device acceptance, incident reporting and recall execution
Course Outline:
Day 1: Medical Device Fundamentals, Classification and Current-State Review
Medical Device Definition, Intended Purpose and Accessories Boundary
Risk-Based Device Classification Concepts: Class I, II and III Logic
In Vitro Diagnostic Devices and Software as a Medical Device at Overview
Device Life-Cycle Roles: Manufacturer, Importer, Distributor and Healthcare User
Device Portfolio Current-State Gap Checklist
Day 2: ISO 13485 Quality Management System for Devices
ISO 13485 Structure and Differences from ISO 9001 Requirements
Design and Development Controls: Inputs, Outputs, Verification, Validation and Transfer
Purchasing Controls and Supplier Evaluation for Critical Components
Traceability, UDI Device Identifiers and Implantable Device Records
Sterile Process Validation and Production Process Validation Protocols
Day 3: ISO 14971 Risk Management Process Application
Risk Management Plan and Risk Acceptability Criteria Matrix
Hazard Identification Using Intended Use, Foreseeable Misuse and Hazard Checklists
Risk Estimation: Probability of Harm and Severity Scoring Tables
Failure Mode and Effects Analysis and Fault Tree Analysis for Device Hazards
ISO/TR 24971 Guidance on Applying the Risk Management Standard
Day 4: Risk Controls, Benefit-Risk, Usability, Software and Post-Market Feedback
Risk Control Option Hierarchy: Inherent Safety, Protective Measures and Information for Safety
Overall Residual Risk Evaluation and Benefit-Risk Analysis Record
Usability Engineering Overview: Use Errors, User Interface Hazards and Summative Evaluation
Software Hazard Analysis and Cybersecurity Risk for Connected Devices
Post-Market Surveillance Plan, Complaint Trending, Vigilance Reporting and Field Safety Corrective Actions
Day 5: Case Study Workshop: Device Risk Management File
Case Brief: Infusion Pump Adverse Event and Hospital Recall Execution
Case Brief: Mobile Health App Reclassified as Software as a Medical Device
Technical Documentation Index and Risk Traceability Matrix Build
Risk Management Report Drafting and Production and Post-Production Information Loop
Device Risk Management File Presentation to a Peer Review Panel
Skills You Will Gain:
Device Risk Classification
Design Control Documentation
Hazard Analysis
Failure Mode and Effects Analysis
Residual Risk Justification
Usability Risk Screening
Post-Market Surveillance Planning
Field Safety Corrective Action Handling
Why Attend This Course:
Return with a Device Risk Management File for a product from your own portfolio, ready for internal review
Link complaints, service reports and incident data to specific hazards so risk estimates are updated from evidence
Handle recalls and field safety notices with defined roles for manufacturer, distributor and hospital teams
Compare device risk practice with peers from manufacturing, distribution and hospital biomedical engineering
Conclusion:
Safe medical devices depend on a risk file that stays live from the first design input to the last unit in clinical use. The course moves from device classification and the ISO 13485 quality management system through the ISO 14971 process, risk controls, benefit-risk decisions, usability and software hazards, to post-market surveillance, vigilance and recalls. The final day turns this into a Device Risk Management File ready for review by quality, regulatory and clinical engineering leads.
Medical Device Risk Management and Quality Systems: ISO 14971 and ISO 13485 runs in London over 5 days, with 2 upcoming dates in London. The course fee is 23,000 SAR.
Looking for training courses in London? CoreConsept Training Center delivers professional training in London across governance, leadership, ESG, project management and digital transformation — open enrolment programmes in central London venues.