Cooling Towers and Cooling Water Treatment: Operation, Maintenance and Troubleshooting – Paris, 9–13 Aug 2027
DestinationParis
Dates9 – 13 August 2027
Reference270_11845
This session
9–13 Aug 2027
This Cooling Towers and Cooling Water Treatment: Operation, Maintenance and Troubleshooting session in Paris runs from Monday 9 August to Friday 13 August 2027 (week 32, Q3 2027). It is the 1st of 2 dates in Paris in 2027, at a fee of 23,500 SAR, the same for each of them. Registration is open for this date. It is held in person at Right Bank business hotel.
DatesMonday 9 Aug – Friday 13 Aug 2027
Week32 of 2027
Duration5 days
Fee23,500 SAR
StatusOpen for registration
FormatIn person
VenueRight Bank business hotel
Programme overview
Introduction:
Cooling towers in refineries, power stations, petrochemical and manufacturing plants often lose capacity without anyone noticing: fill scales or clogs, nozzles block, fans run off pitch, cycles of concentration drift and biofilm builds in the basin. The result is higher cold water temperature, lost production, wasted make-up water and Legionella exposure. This Core Concept course gives utility, operations and water treatment teams the methods to read tower performance, run the circulating water chemistry, test, inspect and troubleshoot cooling towers. Participants build a Cooling Tower Performance and Water Management Plan for their own site.
Course Objectives:
Calculate range, approach, heat load and liquid-to-gas ratio from site readings and wet-bulb data to judge cooling tower capability
Inspect fill, distribution systems, drift eliminators, fans, gearboxes and drive shafts against condition criteria and record defects
Control cycles of concentration, blowdown, scaling, corrosion and biofouling through a documented cooling water treatment programme
Apply a written Legionella risk control scheme covering monitoring, sampling, cleaning and disinfection of cooling towers
Diagnose high cold water temperature, water losses and mechanical faults and select corrective actions
Produce a Cooling Tower Performance and Water Management Plan with water and fan energy saving measures for their own site
Target Audience:
Utility and operations engineers responsible for cooling tower cells, circulating water pumps and cold water temperature targets
Maintenance engineers and supervisors responsible for fans, gearboxes, fill and structural repairs on cooling towers
Water treatment and laboratory staff responsible for chemical dosing, blowdown control and water quality monitoring
Shift operators and technicians responsible for daily tower rounds, log sheets and basin checks
Reliability and energy engineers responsible for tower performance, water use and fan power consumption
Course Outline:
Day 1: Cooling Tower Fundamentals and the Site Baseline
Evaporative Heat Rejection: Latent and Sensible Heat Transfer at the Air-Water Interface
Wet-Bulb and Dry-Bulb Readings on the Psychrometric Chart for Tower Duty
Natural Draft, Induced Draft and Forced Draft Tower Arrangements
Counterflow Versus Crossflow Water and Air Paths and Their Operating Trade-Offs
Tower Baseline Survey: Cell Register, Design Data Sheet and Log Sheet Review
Day 2: Thermal Performance and Tower Components
Range, Approach and Heat Load Calculation from Field Readings
Liquid-to-Gas (L/G) Ratio and Its Effect on Cold Water Temperature
Splash Fill Versus Film Fill: Fouling Tolerance and Replacement Criteria
Hot Water Basins, Spray Nozzles and Drift Eliminator Condition Checks
Fan, Gearbox, Drive Shaft and Motor Assembly with Vibration Cut-Out Switches
Day 3: Cooling Water Chemistry and the Treatment Programme
Evaporation, Drift and Blowdown Water Balance with Make-Up Metering
Cycles of Concentration Calculation and Conductivity-Controlled Blowdown Setpoints
Scaling Indices and Calcium Carbonate and Silica Scale Control with Inhibitors
Corrosion Coupons and Inhibitor Dosing for Mixed-Metal Circulating Circuits
Oxidising and Non-Oxidising Biocide Programmes with Dip Slide Monitoring
Day 4: Legionella Control, Performance Testing and Troubleshooting
Legionella Risk Assessment, Written Control Scheme and Sampling Plan
Cleaning and Disinfection Procedure for Basins, Fill Packs and Distribution Decks
Thermal Performance Test Procedure: Instrument Placement, Test Conditions and Capability Result
High Cold Water Temperature Diagnosis: Plume Recirculation, Fill Blockage and Uneven Distribution
Mechanical Fault Diagnosis: Gearbox Oil Analysis, Fan Blade Pitch and Shaft Misalignment
Day 5: Inspection Walkthrough and the Cooling Tower Performance and Water Management Plan
Inspection Walkthrough Checklist: Structure, Casing, Fill, Eliminators, Basin and Fan Deck
Petrochemical Case: Rising Approach Traced to Scaled Fill and Blocked Nozzles
Power Station Case: Condenser Backpressure Linked to Tower Capacity Shortfall
Cooling Tower Performance and Water Management Plan Build and Peer Review
Skills You Will Gain:
Tower Thermal Performance Analysis
Psychrometric Calculation
Fill and Drift Eliminator Inspection
Fan and Gearbox Condition Assessment
Cooling Water Chemistry Control
Blowdown Optimisation
Legionella Risk Management
Cooling Tower Troubleshooting
Why Attend This Course:
Return with a Cooling Tower Performance and Water Management Plan built from your own site's tower data and water readings
Recover lost cooling capacity by tracing high approach to fill, distribution, airflow or mechanical causes before the hot season
Cut make-up water, chemical and fan power costs with measures you can justify to plant management using water balance figures
Compare cooling tower and water treatment practice with peers from refining, power, petrochemical and manufacturing plants
Conclusion:
A cooling tower that is measured, treated and inspected against clear criteria holds its cold water temperature and wastes little water. The week moves from evaporative heat rejection, psychrometrics and tower types, through range, approach, fill and mechanical components, to cooling water chemistry, blowdown and Legionella control, then to performance testing and troubleshooting. The final day applies these in an inspection walkthrough and case work, producing a Cooling Tower Performance and Water Management Plan ready for the next plant review.
Cooling Towers and Cooling Water Treatment: Operation, Maintenance and Troubleshooting runs in Paris over 5 days, with 2 upcoming dates in Paris. The course fee is 23,500 SAR.
Looking for training courses in Paris? CoreConsept Training Center delivers professional training in Paris across European regulatory frameworks, leadership, ESG, governance and project management — open enrolment programmes in central Paris.