Power Quality and Harmonics: Power Factor Correction, Filtering and Site Audits – London, 12–16 Apr 2027
DestinationLondon
Dates12 – 16 April 2027
Reference299_12249
This session
12–16 Apr 2027
This Power Quality and Harmonics: Power Factor Correction, Filtering and Site Audits session in London runs from Monday 12 April to Friday 16 April 2027 (week 15, Q2 2027). It is the 2nd of 2 dates in London in 2027, at a fee of 23,000 SAR, the same for each of them. Registration is open for this date. It is held in person at Central London four-star.
DatesMonday 12 Apr – Friday 16 Apr 2027
Week15 of 2027
Duration5 days
Fee23,000 SAR
StatusOpen for registration
FormatIn person
VenueCentral London four-star
Programme overview
Introduction:
Power quality problems cost industrial and commercial sites through tripped processes, overheated transformers and neutrals, failed capacitor banks and reactive energy penalties, yet many sites have no measured picture of what their network actually carries. This Core Concept course equips electrical engineers to classify disturbances, trace harmonic sources, measure with power quality analysers, judge results against recognised limits and design power factor correction, harmonic filtering and sag ride-through solutions. Participants produce a Power Quality Audit Report and Mitigation Plan for a network from their own site.
Course Objectives:
Classify voltage sags, swells, transients, flicker, unbalance and waveform distortion from recorded events and link each to its likely cause on the network
Quantify harmonic currents from drives, rectifiers, LED lighting and IT loads and calculate their heating effect on transformers, cables and neutral conductors
Plan and run a power quality measurement campaign with a class-rated analyser and interpret the data against IEEE Standard 519 and EN 50160 limits
Size capacitor banks and detuned reactors for power factor correction and check the design for parallel resonance with the supply
Select between passive filters, active harmonic filters, UPS and dynamic voltage restorers for a given disturbance and justify the choice on cost and performance
Calculate energy and reactive power tariff savings and assemble a power quality audit with prioritised mitigation actions
Target Audience:
Plant electrical engineers responsible for supply performance and nuisance tripping on process and utility networks
Facility and building services engineers responsible for data halls, lifts, lighting and HVAC loads in commercial buildings
Power quality and energy engineers who carry out site measurements and reactive power audits
Electrical design engineers who specify capacitor banks, harmonic filters and ride-through equipment for new installations
Maintenance engineers who investigate capacitor failures, overheated neutrals and unexplained equipment damage
Course Outline:
Day 1: Power Quality Phenomena and Site Disturbance Profiling
IEEE 1159 Disturbance Categories: Transients, Short and Long Duration Variations
Voltage Sag and Swell Magnitude-Duration Characterisation from Event Records
Flicker Perception, Voltage Fluctuation and Arc Furnace and Welder Sources
Voltage Unbalance Calculation and Its Negative-Sequence Heating Impact
Site Power Quality Complaint Log and Sensitive Load Register
Day 2: Harmonic Theory, Sources and Recognised Limits
Fourier Spectrum, THD, TDD and Crest Factor Definitions with Worked Values
Six-Pulse and Twelve-Pulse Rectifier, Switch-Mode Supply and LED Driver Spectra
Triplen Harmonics in Four-Wire Networks and Neutral Conductor Overloading
IEEE Standard 519 Point of Common Coupling Current and Voltage Distortion Limits
EN 50160 Voltage Characteristics and EN 61000-3-2 Equipment Emission Classes
Day 3: Power Quality Measurement and Analyser Data Interpretation
IEC 61000-4-30 Class A Analyser Functions and Aggregation Intervals
IEC 61000-4-7 Harmonic and Interharmonic Grouping Method
Current Transformer, Voltage Probe and Logger Connection Plan for Three-Phase Surveys
Trend, Histogram and Cumulative Probability Reading of a One-Week Survey
Transformer Derating and K-Factor Estimation from Measured Harmonic Currents
Day 4: Power Factor Correction, Resonance and Mitigation Design
Reactive Power Demand Calculation and Stepped Automatic Capacitor Bank Sizing
Parallel Resonance Frequency Check Using Supply Short-Circuit Level and Bank Rating
Detuned Reactor Tuning Factor Selection and Capacitor Voltage Rating Uplift
Passive Tuned Filters Versus Active Harmonic Filters and Hybrid Schemes
Sag Ride-Through Options: UPS, Dynamic Voltage Restorer and Static Transfer Switch
Day 5: Power Quality Audit Case Work and Mitigation Plan
Manufacturing Plant Case: Drive-Rich Network with Failing Capacitor Bank
Commercial Building Case: IT and LED Loads with Overheated Neutral and Transformer
Reactive Energy Tariff Penalty and Loss Reduction Payback Calculation
Power Quality Audit Report and Mitigation Plan Drafting
Peer Review Panel and Mitigation Priority Defence
Skills You Will Gain:
Disturbance Classification
Harmonic Spectrum Analysis
Power Quality Survey Planning
Analyser Data Interpretation
Capacitor Bank Sizing
Resonance Risk Assessment
Harmonic Filter Selection
Reactive Power Savings Appraisal
Why Attend This Course:
Return with a Power Quality Audit Report and Mitigation Plan for a network from your own site, tested in case work and peer review
Stop repeat capacitor failures, overheated neutrals and nuisance trips by tying each symptom to a measured cause
Specify correction and filtering equipment that will not create new resonance problems on your network
Compare measurement data and mitigation results with engineers from manufacturing, commercial buildings, utilities, oil and gas and healthcare facilities
Conclusion:
Power quality improves when disturbances are measured, traced to their sources and corrected with equipment chosen for the network it joins. The course moves from disturbance categories and site profiling, through harmonic theory and recognised limits, to analyser measurement and data interpretation, then to power factor correction, resonance checks, filtering and sag ride-through. The final day applies these methods to plant and building cases and produces a Power Quality Audit Report and Mitigation Plan ready for engineering and budget approval.
Power Quality and Harmonics: Power Factor Correction, Filtering and Site Audits runs in London over 5 days, with 2 upcoming dates in London. The course fee is 23,000 SAR.