Power System Stability and Blackout Prevention: Load Shedding, Black Start and Restoration – Paris, 30 Aug – 10 Sep 2027
DestinationParis
Dates30 August – 10 September 2027
Reference305_12335
This session
30 Aug – 10 Sep 2027
This Power System Stability and Blackout Prevention: Load Shedding, Black Start and Restoration session in Paris runs from Monday 30 August to Friday 10 September 2027 (week 35, Q3 2027). It is the 2nd of 2 dates in Paris in 2027, at a fee of 42,300 SAR, the same for each of them. Registration is open for this date. It is held in person at Right Bank business hotel.
DatesMonday 30 Aug – Friday 10 Sep 2027
Week35 of 2027
Duration12 days
Fee42,300 SAR
StatusOpen for registration
FormatIn person
VenueRight Bank business hotel
Programme overview
Introduction:
Power system stability is tested in seconds: a line trip, a lost generator or a slow voltage decline can turn into a wide-area blackout long before operators understand the sequence, and restoration then depends on plans that were rarely drilled. This Core Concept course prepares transmission, generation and control-room staff to read frequency, voltage and rotor angle behaviour, design defence measures such as load shedding, remedial action schemes and controlled islanding, and restart a grid from black start sources. Participants produce a Blackout Risk Review and Restoration Plan for a sample grid.
Course Objectives:
Classify a disturbance by its frequency, voltage and rotor angle signature and state which operating state the system has entered
Calculate inertia, droop and reserve effects on frequency nadir after a large infeed loss and check reserve sizing against it
Assess voltage stability margin from PV and QV curves and plan reactive reserves that prevent long-term voltage collapse
Design under-frequency and under-voltage load shedding stages, remedial action schemes and islanding boundaries for a transmission network
Prepare a black start and restoration plan with cranking paths, island resynchronisation and load pickup sequence
Run restoration drills and review stability margins for grids with a growing share of inverter-based resources
Target Audience:
Transmission system engineers who carry out operational security, contingency and stability studies
Control-room dispatchers and shift supervisors who act on alarms, reserves and emergency switching
Generation engineers responsible for unit frequency response, reactive capability and black start readiness
Operation planning engineers who prepare outage schedules, defence plans and restoration procedures
Grid code and system operation specialists who review generator performance and ride-through behaviour
Course Outline:
Day 1: Power System Operation Fundamentals and Security States
Generation-Load Balance, Economic Dispatch and Control Area Responsibilities
N-1 Security Criterion and Normal, Alert, Emergency and Restorative Operating States
Stability Classification into Rotor Angle, Frequency and Voltage Families
SCADA and EMS Control-Room Displays, State Estimation and Contingency Alarms
Blackout Anatomy: Initiating Event, Cascade Phase and Collapse Sequence
Day 2: Frequency Control, Inertia and Operating Reserves
System Inertia, Swing Equation and Rate of Change of Frequency (ROCOF)
Governor Droop Response and Primary Frequency Containment Reserve
Load-Frequency Control, Area Control Error and Secondary Reserve Activation
Tertiary Reserve Scheduling and Largest Credible Infeed Loss Sizing
Frequency Nadir and Settling Point Calculation for a Generator Trip
Day 3: Voltage Stability and Reactive Power Management
Reactive Power Sources: Generator Capability Curves, Capacitor Banks, SVC and STATCOM
PV and QV Curve Analysis and Loadability Margin to the Nose Point
On-Load Tap Changer Action and Load Recovery in Long-Term Voltage Collapse
Overexcitation Limiter Operation and Reactive Reserve Monitoring
Voltage Control Hierarchy and Reactive Power Dispatch Schedules
Day 4: Rotor Angle Stability and Wide-Area Monitoring Tools
Power-Angle Curve and Equal Area Criterion for Transient Stability
Critical Clearing Time and Fault Duration Effects on Synchronism
Small-Signal Oscillations: Local and Inter-Area Modes and Damping Ratio
Power System Stabiliser Role and Modal Analysis Output Interpretation
Phasor Measurement Units and Wide-Area Oscillation Detection Displays
Day 5: Cascading Failures and Major Blackout Lessons: Guided Case Study
Cascade Mechanisms: Overload Transfer, Hidden Failures and Backup Zone Trips
Major Interconnection Blackouts as Published Investigation Reports Describe Them
Vegetation Contact, Situational Awareness and Alarm Handling Gaps in Blackout Sequences
Event Timeline Reconstruction from Sequence-of-Events and Disturbance Logs
Week-One Debrief: Frequency, Voltage and Angle Signatures in One Disturbance
Day 6: Defence Plans: Load Shedding, Special Protection Schemes and Islanding
Under-Frequency Load Shedding Stage Design: Thresholds, Load Blocks and Time Delays
Under-Voltage Load Shedding Logic for Delayed Voltage Recovery
Special Protection and Remedial Action Schemes: Generator Tripping and Arming Logic
Controlled Islanding Boundaries and Separation Point Selection
Island Frequency and Voltage Control with Limited Generation
Day 7: Black Start Capability, Restoration Strategy and Plan Governance
Black Start Unit Types: Hydro, Diesel, Open Cycle Gas Turbine and Battery Storage
Cranking Paths, Energisation Sequences and Overvoltage on Lightly Loaded Lines
Bottom-Up, Top-Down and Hybrid Restoration with Island Resynchronisation
Cold Load Pickup, Load Block Sizing and Synchronism Check Criteria
Black Start Service Procurement, Capability Testing and Restoration Plan Approval
Day 8: Emergency Coordination, Operator Drills and Communication
Emergency Operating Procedures and Dispatcher Authority During System Emergencies
Coordination Protocols Between Transmission Operator, Generators and Distribution Utilities
Restoration Drill Design Using Dispatcher Training Simulator Scenarios
Critical Load Customer Notification and Public Information Plans
Post-Event Investigation Reports and Lessons Learned Action Tracking
Day 9: Low-Inertia Grids, Inverter-Based Resources and Resilience Metrics
Inverter-Based Resource Fault Current Limits and Short Circuit Ratio Assessment
Grid-Forming Converters, Synchronous Condensers and Fast Frequency Response
Fault Ride-Through Behaviour and Loss of Distributed Generation in Disturbances
SAIDI, CAIDI and Unserved Energy Tracking After Major Events
Stability Margin Dashboard: ROCOF Limits, Reactive Reserve and Minimum Inertia
Day 10: Capstone: Blackout Risk Review and Restoration Plan for a Sample Grid
Sample Grid Briefing: Network Model, Generation Mix and Critical Contingencies
Blackout Risk Register Build with Credible Cascade Likelihood and Consequence Scoring
Defence Plan Check Against Load Shedding Stages, Remedial Schemes and Island Points
Restoration Plan Drafting: Black Start Sources, Cranking Paths and Load Pickup Order
Blackout Risk Review and Restoration Plan Presentation and Peer Challenge
Skills You Will Gain:
Disturbance Signature Analysis
Frequency Response Assessment
Reactive Reserve Planning
Load Shedding Scheme Design
Controlled Islanding Strategy
Black Start Sequence Planning
Restoration Drill Facilitation
Low-Inertia Grid Assessment
Why Attend This Course:
Return with a Blackout Risk Review and Restoration Plan built and challenged on a sample grid, ready to adapt to your own network
Recognise the early frequency, voltage and oscillation signs of a cascade and know which defence action applies
Rehearse restoration decisions under time pressure in simulated control-room scenarios before a real event demands them
Compare operating and restoration practice with engineers from utilities, independent generators, industrial networks and system operators
Conclusion:
Blackout prevention rests on knowing how a grid loses stability and having tested plans for both defence and recovery. The first week builds that understanding through operating states, frequency control, voltage stability, rotor angle behaviour and cascade case study. The second week adds what a short course leaves out: load shedding and remedial scheme design, islanding, black start and restoration strategy, emergency coordination and drills, and low-inertia challenges. The final day brings these together in a Blackout Risk Review and Restoration Plan presented for peer challenge.
Power System Stability and Blackout Prevention: Load Shedding, Black Start and Restoration runs in Paris over 12 days, with 2 upcoming dates in Paris. The course fee is 42,300 SAR.