ICP-OES, ICP-MS and AAS: Elemental Analysis, Interferences and QC – Dubai, 22–26 Feb 2027
DestinationDubai
Dates22 – 26 February 2027
Reference377_13339
This session
22–26 Feb 2027
This ICP-OES, ICP-MS and AAS: Elemental Analysis, Interferences and QC session in Dubai runs from Monday 22 February to Friday 26 February 2027 (week 8, Q1 2027). It is the 1st of 2 dates in Dubai in 2027, at a fee of 19,500 SAR, the same for each of them. Registration is open for this date. It is held in person at Five-star CBD venue.
DatesMonday 22 Feb – Friday 26 Feb 2027
Week8 of 2027
Duration5 days
Fee19,500 SAR
StatusOpen for registration
FormatIn person
VenueFive-star CBD venue
Programme overview
Introduction:
Metals and trace element results from ICP-OES, ICP-MS and atomic absorption spectroscopy decide whether crude, catalysts, drinking water, effluent, ores and foodstuffs pass their limits, yet incomplete digestion, uncorrected spectral overlaps, drifting plasma conditions and thin QC records still send wrong numbers to clients and regulators. This Core Concept course takes laboratory analysts from atomic spectroscopy principles through flame and graphite furnace AAS, plasma instrumentation, microwave digestion, interference correction, calibration, QC samples and instrument care. Participants build an Elemental Analysis Method Sheet and QC Plan for one analyte suite from their own laboratory.
Course Objectives:
Select flame AAS, graphite furnace AAS, ICP-OES or ICP-MS for an analyte list by matching detection needs, matrix load and sample throughput
Prepare solid, oil and aqueous samples for metals determination using acid dilution, hotplate and closed-vessel microwave digestion without loss or contamination
Identify spectral, polyatomic, isobaric and matrix interferences and apply background correction, interelement correction or collision/reaction cell settings to remove them
Build calibrations with external standards, matrix matching, standard additions and internal standards and verify them with independent check solutions
Run the QC sample sequence of blanks, fortified blanks, fortified matrices and continuing checks and estimate detection limits, linear range and spike recovery for a metals method
Maintain nebulisers, spray chambers, torches, interface cones, lamps and graphite tubes and trace drift or sensitivity loss to its cause before results are reported
Target Audience:
Analysts who prepare samples and run AAS, ICP-OES or ICP-MS measurements for metals and trace elements
Chemists who develop, verify and document elemental analysis methods for water, environmental, mining, food or petroleum samples
Instrument operators who tune plasma and furnace systems and carry out routine user maintenance
Senior technicians who review metals data batches and approve results for reporting
Quality control staff who schedule QC samples and follow up failed checks in elemental analysis sections
Course Outline:
Day 1: Atomic Spectroscopy Principles and Technique Selection
Atomic Absorption, Atomic Emission and Ion Formation: Energy Levels and Characteristic Wavelengths
Beer-Lambert Relationship and Emission Intensity Versus Concentration
Method Detection Limit from Seven Replicates and Limit of Quantitation Setting
Linear Dynamic Range, Spike Recovery and Duplicate Precision Acceptance Windows
Plasma Tuning Checks with Magnesium and Lead Isotopes and Short-Term Stability Tests
Maintenance and Fault Tracing: Blocked Nebulisers, Worn Cones, Torch Deposits, Weak Lamps and Tube Ageing
Day 5: Case Study Workshop: Elemental Analysis Method Sheet and QC Plan
Case Study: Wear Metal Panel in Used Lubricating Oil by ICP-OES
Case Study: Trace Arsenic, Lead and Cadmium in Drinking Water by ICP-MS
Case Study: Failed Internal Standard Recovery and Batch Rerun Decision
Build: Elemental Analysis Method Sheet and QC Plan for an Own-Laboratory Analyte Suite
Metals Data Review Checklist and Certificate Reporting Peer Review
Skills You Will Gain:
Atomic Spectrometry Technique Selection
Microwave Acid Digestion
Spectral Interference Correction
Internal Standardisation
Detection Limit Estimation
Plasma Instrument Tuning
Sample Introduction System Care
Metals Data Review
Why Attend This Course:
Leave with an Elemental Analysis Method Sheet and QC Plan for an analyte suite your laboratory already runs, ready for supervisor sign-off
Reduce reruns and lost plasma time by recognising a digestion, interference or hardware fault from the QC pattern it leaves
Answer client and auditor questions on metals results with documented detection limits, recoveries and interference corrections
Compare elemental analysis practice with analysts from refinery, utility, environmental, mining and food testing laboratories
Conclusion:
Defensible metals results rest on the right atomic spectrometry technique, a complete digestion, corrected interferences, a stable calibration and a QC sequence that catches drift before it reaches a certificate. The course moves from absorption and emission principles through AAS, ICP-OES and ICP-MS hardware, then to digestion, calibration, internal standards and interference removal, before detection limits, QC samples and instrument upkeep. The final day turns this into an Elemental Analysis Method Sheet and QC Plan participants can use at their next batch review.
ICP-OES, ICP-MS and AAS: Elemental Analysis, Interferences and QC runs in Dubai over 5 days, with 2 upcoming dates in Dubai. The course fee is 19,500 SAR.
Looking for training in Dubai? CoreConsept Training Center delivers professional courses in Dubai across leadership, governance, ESG, project management and digital transformation — open enrolment and in-house programmes for the Gulf region.