Diesel Generator Maintenance and Testing: Engine Systems, Paralleling, ATS and Load-Bank Tests – Dubai, 31 May – 4 Jun 2027
DestinationDubai
Dates31 May – 4 June 2027
Reference410_13742
This session
31 May – 4 Jun 2027
This Diesel Generator Maintenance and Testing: Engine Systems, Paralleling, ATS and Load-Bank Tests session in Dubai runs from Monday 31 May to Friday 4 June 2027 (week 22, Q2 2027). It is the 1st of 2 dates in Dubai in 2027, at a fee of 19,500 SAR, the same for each of them. Registration is open for this date. It is held in person at Five-star CBD venue.
DatesMonday 31 May – Friday 4 Jun 2027
Week22 of 2027
Duration5 days
Fee19,500 SAR
StatusOpen for registration
FormatIn person
VenueFive-star CBD venue
Programme overview
Introduction:
Diesel generator maintenance decides whether a set will start, accept load and run whenever mains power fails, yet many standby units sit idle for months with contaminated fuel, light-load carbon build-up and transfer switches nobody has exercised under load. This Core Concept course gives technicians and engineers a practical method to operate, maintain and test diesel generator sets, from the engine's fuel, air, cooling, lubrication and starting systems to the alternator, governor, paralleling controls and automatic transfer switch. Participants build a Genset Reliability and Load Test Programme for a unit at their own site.
Course Objectives:
Identify the engine, alternator and control components of an installed diesel generator set and confirm its standby, prime or continuous rating against the connected load
Inspect and service the fuel injection, air intake, turbocharger, cooling, lubrication and starting systems to the manufacturer's schedule
Operate generator sets in parallel by synchronising them and setting governor droop and voltage control so that kW and kVAr are shared between units
Test automatic transfer switch sequences and carry out commissioning and periodic load-bank tests with correct acceptance records
Diagnose failure to start, black smoke, overheating, low oil pressure and hunting faults using alarm logs, readings and a structured fault-finding sequence
Compile a preventive maintenance schedule, fuel management routine and load test programme that keeps standby units ready to run
Target Audience:
Mechanical and electrical technicians responsible for routine servicing and first-line fault finding on diesel generator sets
Plant and utility engineers responsible for the availability of emergency, standby and prime power units
Facilities and building services staff responsible for standby power at hospitals, data centres, airports and commercial sites
Shift operators responsible for starting, loading, paralleling and shutting down generator sets
Maintenance planners responsible for genset service intervals, spares and test records
Course Outline:
Day 1: Diesel Generator Set Anatomy, Ratings and Duty
Genset Package Layout: Engine, Alternator, Base Frame, Canopy, Control Panel and Circuit Breaker
Four-Stroke Compression Ignition Cycle and Engine Nameplate Data
Standby, Prime and Continuous Ratings Under ISO 8528 and ISO 3046 Definitions
Load Survey Worksheet: kW, kVA, Motor Starting Surge and Non-Linear Loads
Installed Genset Baseline Survey: Running Hours, Service History and Alarm Records
Day 2: Engine Systems: Fuel, Air, Cooling, Lubrication and Starting
Fuel Injection Systems: Common Rail, Unit Injector and Mechanical Pump Arrangements
Air Intake, Turbocharger and Charge Air Cooler Inspection Points
Jacket Water Cooling Circuit, Radiator, Thermostat and Coolant Condition Checks
Engine Lubrication Circuit, Oil and Filter Change Intervals and Oil Sampling Point
Electric and Air Starting Systems, Jacket Water Heater and Cold-Start Aids
Day 3: Alternator, Governor, Paralleling and Transfer Switching
Brushless Alternator Construction and AVR Interaction with Engine Speed Governor
Isochronous and Droop Speed Governing During Load Acceptance
Synchronising Checks and Paralleling Panel Sequence for Multiple Generator Sets
kW and kVAr Load Sharing Between Parallel Units
Automatic Transfer Switch Operation: Open Transition and Closed Transition Sequences
Day 4: Load-Bank Testing, Fuel Management and Fault Diagnosis
Commissioning Test Sequence and Resistive and Reactive Load-Bank Test Procedure
Wet Stacking at Light Load: Symptoms, Prevention and Corrective Loaded Runs
Diesel Fuel Storage, Water and Microbial Contamination Checks and Fuel Polishing
Generator Protection Functions at Overview: Overcurrent, Reverse Power and Engine Shutdowns
Fault-Finding Chart: Failure to Start, Black Smoke, Overheating, Low Oil Pressure and Hunting
Day 5: Genset Inspection Walkthrough and Reliability Programme
Guided Inspection Walkthrough of a Case Standby Generator Room and Fuel Day Tank
Exhaust Emissions and Noise Control Measures at Overview: Silencer, Enclosure and Aftertreatment
Preventive Maintenance Schedule by Daily, Weekly, Monthly and Annual Task Lists
Test Record Review from a Case Load-Bank Run and Transfer Switch Exercise
Genset Reliability and Load Test Programme Drafting and Peer Review
Skills You Will Gain:
Genset Rating Verification
Diesel Engine System Servicing
Governor Droop Setting
Generator Paralleling Practice
Transfer Switch Testing
Load-Bank Test Execution
Fuel Contamination Control
Genset Fault Diagnosis
Why Attend This Course:
Return with a Genset Reliability and Load Test Programme written for a diesel generator set at your own site
Catch contaminated fuel, light-load carbon build-up and weak starting systems before a mains failure exposes them
Run load-bank and transfer switch tests with a clear sequence and acceptance record that auditors and managers can follow
Compare generator practice with peers from utilities, oil and gas, hospitals, data centres and industrial plants
Conclusion:
A standby generator is only dependable when its engine systems are serviced, its fuel is kept clean and it is proven under real load. The one week move from genset anatomy and ratings, through fuel, air, cooling, lubrication and starting systems, to the alternator, governor, paralleling and transfer switching, then to load-bank testing, fuel management and fault diagnosis. The final day applies these methods in an inspection walkthrough and closes with a Genset Reliability and Load Test Programme ready for site use.
Diesel Generator Maintenance and Testing: Engine Systems, Paralleling, ATS and Load-Bank Tests runs in Dubai over 5 days, with 2 upcoming dates in Dubai. The course fee is 19,500 SAR.
Looking for training in Dubai? CoreConsept Training Center delivers professional courses in Dubai across leadership, governance, ESG, project management and digital transformation — open enrolment and in-house programmes for the Gulf region.