Industrial Rectifiers and Power Converters: TR Unit Maintenance and Fault Analysis – Paris, 30 Aug – 3 Sep 2027
DestinationParis
Dates30 August – 3 September 2027
Reference822_20289
This session
30 Aug – 3 Sep 2027
This Industrial Rectifiers and Power Converters: TR Unit Maintenance and Fault Analysis session in Paris runs from Monday 30 August to Friday 3 September 2027 (week 35, Q3 2027). It is the 2nd of 2 dates in Paris in 2027, at a fee of 23,500 SAR, the same for each of them. Registration is open for this date. It is held in person at Right Bank business hotel.
DatesMonday 30 Aug – Friday 3 Sep 2027
Week35 of 2027
Duration5 days
Fee23,500 SAR
StatusOpen for registration
FormatIn person
VenueRight Bank business hotel
Programme overview
Introduction:
Industrial rectifiers and power converters feed electrolysis cells, plating lines, cathodic protection systems and DC plant buses, yet many sites run them until a thyristor stack fails, a fuse clears without explanation or a transformer-rectifier unit overheats under full load. This Core Concept course gives electrical and instrument staff a practical method to read converter topologies, check firing circuits, test semiconductor devices, commission units and trace faults with oscilloscope traces and thermographic surveys. Participants produce a TR Unit Fault Analysis and Maintenance Plan for a case installation.
Course Objectives:
Identify converter classes and rectifier topologies on site drawings and explain how each shapes output voltage, ripple and supply current
Test diodes, thyristors and IGBTs and interpret device ratings, gate trigger data and thermal limits before replacement
Verify firing circuits, regulation loops and cooling systems and adjust them to hold current and voltage setpoints
Carry out pre-energisation and load commissioning checks on transformer-rectifier units and record acceptance results
Diagnose rectifier and inverter faults using oscilloscope waveforms, fuse evidence, thermographic images and alarm logs
Build a preventive maintenance and spares plan that reduces unplanned outages of rectifier and converter assets
Target Audience:
Electrical maintenance engineers responsible for transformer-rectifier units and DC plant in process, chemical and metals facilities
Electrical and instrument technicians responsible for first-line testing and repair of thyristor and IGBT converter panels
Cathodic protection staff responsible for impressed current rectifier output, adjustment and monitoring
Maintenance planners and supervisors responsible for converter spares, inspection intervals and outage scheduling
Commissioning staff responsible for energising and accepting new or refurbished rectifier installations
Course Outline:
Day 1: Rectifier and Converter Duty in Process Plants
Oscilloscope Diagnosis with Differential Probes and Missing-Pulse Patterns
Day 5: Case TR Unit Walkthrough and Fault Analysis Plan
Guided Inspection Walkthrough of a Case Cathodic Protection and Electrolysis TR Unit
Infrared Thermography Review of Busbar Joints, Fuses and Heatsinks from the Case
Fault Tree Construction from Case Waveforms, Alarm Logs and Trip Records
Preventive Maintenance Task List, Intervals and Critical Spares for Rectifier Stacks
TR Unit Fault Analysis and Maintenance Plan Presentation and Peer Review
Skills You Will Gain:
Converter Topology Identification
Power Semiconductor Testing
Firing Circuit Verification
Converter Cooling Inspection
TR Unit Commissioning
Oscilloscope Waveform Diagnosis
Infrared Thermography Interpretation
Rectifier Spares Planning
Why Attend This Course:
Return with a TR Unit Fault Analysis and Maintenance Plan built on a case installation and ready to adapt to your own units
Find the cause of blown fuses, unbalanced bridge arms and drifting output before a stack fails in service
Read converter waveforms with confidence and tell a firing fault from a device or supply fault
Compare rectifier and converter maintenance practice with peers from chemicals, metals, oil and gas, water and utility plants
Conclusion:
Rectifier and converter reliability depends on staff who can connect a waveform, a hot joint or a blown fuse to its cause. The one week move from converter classes and transformer-rectifier anatomy, through power semiconductors and six- and twelve-pulse topologies, to firing circuits, regulation, cooling and commissioning, then protection, line-side effects and failure modes. The final day applies these methods in a case walkthrough that produces a TR Unit Fault Analysis and Maintenance Plan ready for the next outage review.
Industrial Rectifiers and Power Converters: TR Unit Maintenance and Fault Analysis runs in Paris over 5 days, with 2 upcoming dates in Paris. The course fee is 23,500 SAR.
Looking for training courses in Paris? CoreConsept Training Center delivers professional training in Paris across European regulatory frameworks, leadership, ESG, governance and project management — open enrolment programmes in central Paris.