Environmental Monitoring and Modelling: Air Emissions, Water, Soil and Noise Sampling – Dubai, 11–15 Jan 2027
DestinationDubai
Dates11 – 15 January 2027
Reference128_9838
This session
11–15 Jan 2027
This Environmental Monitoring and Modelling: Air Emissions, Water, Soil and Noise Sampling session in Dubai runs from Monday 11 January to Friday 15 January 2027 (week 2, Q1 2027). It is the 1st of 2 dates in Dubai in 2027, at a fee of 19,500 SAR, the same for each of them. Registration is open for this date. It is held in person at Five-star CBD venue.
DatesMonday 11 Jan – Friday 15 Jan 2027
Week2 of 2027
Duration5 days
Fee19,500 SAR
StatusOpen for registration
FormatIn person
VenueFive-star CBD venue
Programme overview
Introduction:
Industrial sites lose credibility with regulators and neighbours when environmental monitoring produces gaps, unreliable samples or results that nobody can explain. Poorly placed stations, uncalibrated analysers, broken custody records and unvalidated data turn a routine exceedance into an enforcement case. This Core Concept course trains practitioners to design a monitoring programme, measure ambient air and stack emissions, understand dispersion modelling, sample water, soil and noise correctly, and validate and trend the results. Participants work on real site data and produce a Site Environmental Monitoring Plan and Exceedance Response Protocol.
Course Objectives:
Design a site monitoring programme that links each emission source and pathway to parameters, locations and sampling frequency
Plan ambient air quality and stack emission measurements and check continuous emission monitoring system data against its calibration and audit records
Interpret Gaussian plume and AERMOD results, including their meteorological, terrain, source and receptor inputs, against measured ambient concentrations
Collect surface water, groundwater, soil and noise samples with the correct method, preservation, QA/QC samples and chain of custody
Validate monitoring datasets, analyse trends and investigate exceedances to a documented root cause and corrective action
Prepare a monitoring results report and exceedance notification record suitable for submission to the environmental authority
Target Audience:
Environmental engineers who plan and run sampling and emission measurement at operating plants
HSE and environmental officers responsible for permit monitoring conditions and site reporting
Monitoring and laboratory technicians who collect, preserve and analyse field samples
Compliance staff who compile monitoring data and respond to exceedances and authority queries
Operations engineers who maintain analysers, stacks and monitoring stations
Course Outline:
Day 1: Monitoring Programme Design and Site Context
Monitoring Objectives Matrix: Baseline, Operational and Permit Compliance Monitoring
Source Inventory of Stacks, Fugitive Releases, Discharges and Noise Emitters
Conceptual Site Model for Air, Water, Soil and Noise Pathways
Parameter, Location and Sampling Frequency Rationale Worksheet
Monitoring Programme Gap Assessment Against Current Site Practice
Day 2: Ambient Air Quality, Stack Emissions and CEMS
Ambient Air Quality Station Siting, Samplers and Analyser Types
Data Validation Rules: Outliers, Detection Limits, Flags and Data Capture Rates
Trend Analysis with Control Charts, Rolling Averages and Non-Parametric Trend Tests
Exceedance Investigation: Root Cause Analysis and Corrective Action Log
Day 5: Monitoring Case Work and Final Deliverable
Refinery Case: Validating a Quarter of CEMS and Ambient Station Data
Power and Cement Case: Comparing Modelled and Measured Ground-Level Concentrations
Manufacturing Case: Groundwater Trend Review and Exceedance Response
Monitoring Results Report and Authority Notification Record Drafting
Site Environmental Monitoring Plan and Exceedance Response Protocol Peer Review
Skills You Will Gain:
Monitoring Programme Design
Ambient Air Measurement
Stack Emission Testing
CEMS Data Review
Dispersion Model Interpretation
Field Sampling Technique
Environmental Data Validation
Exceedance Root Cause Analysis
Why Attend This Course:
Return with a Site Environmental Monitoring Plan and Exceedance Response Protocol built from real plant data
Defend sample results and analyser data during audits because every step from field to laboratory is documented
Spot drifting analysers, poor station siting and questionable trends before they become reportable exceedances
Compare field practice with peers from refining, power, cement, chemicals and manufacturing sites
Conclusion:
Monitoring data only protects an industrial site when it is planned around real sources and pathways, collected correctly and checked before anyone relies on it. This course moves from programme design, through ambient air, stack and CEMS measurement, water, soil and noise sampling, to dispersion modelling, data validation, trend analysis and exceedance investigation. The final day applies these methods to refinery, power and manufacturing cases and produces a Site Environmental Monitoring Plan and Exceedance Response Protocol ready for use on site.
Environmental Monitoring and Modelling: Air Emissions, Water, Soil and Noise Sampling runs in Dubai over 5 days, with 2 upcoming dates in Dubai. The course fee is 19,500 SAR.
Looking for training in Dubai? CoreConsept Training Center delivers professional courses in Dubai across leadership, governance, ESG, project management and digital transformation — open enrolment and in-house programmes for the Gulf region.